High Limit Horizontal Mount Aquastat Relay, 8°F differential Zoom

High Limit Horizontal Mount Aquastat Relay, 8°F differential

SKU:L8148A1017

Brand: Honeywell

Honeywell
Qty Price
$119.95
/ each
$470.20 / box (4 units x $117.55)
In Stock! Ships in 24-48 Hours
73 Available

Specs

Application: High Limit
Temperature Range (F): 120°F to 240°F
Switch Action: SPST
Electrical Rating: Circulator: 3.7 A @ 240 Vac
Burner: 3.7 A @ 240 Vac
Burner: 7.4 A @ 120 Vac
Circulator: 7.4 A @ 120 Vac
0.25 A @ 0.25 to 12 Vdc
Electrical Ratings (ALR): Circulator: 22.2 A @ 240 Vac
Circulator: 44.4 A @ 120 Vac
Burner: 44.4 A @ 120 Vac
Burner: 22.2 A @ 240 Vac
Differential:
?
Fixed
8°F
Height: 4-1/8"
Width: 6-1/8"
Depth: 3-1/8"
Operating Humidity: 0% to 95% (non-condensing)
Max PSI:
?
255 psi @ Immersion Well
Mount: Horizontal
Max Ambient: 150F with 1.2A 24V Load
77F with 1.4A 24V Load
Connection Type: Quick-Connect
Capillary Length: 4-1/2"
Anticipator Rating: 0.2 A
Setpoint Temp Range: 240 F
Voltage:
?
120v
Frequency: 60 Hz

Description for Honeywell L8148A1017

Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors.
Features

  • High limit opens burner circuit only.
  • Include transformer and accessory terminals for adding a remote low limit controller.
  • Case available for horizontal or vertical mounting.
  • Requires a 24 Vac thermostat with heat anticipator set at 0.2A.
  • TRADELINE models include well adapter, tube of heat conductive compound and range stops.

  • Product Specifications
    Description: High Limit Aquastat Relay with 8 F fixed differential
    Application: High Limit
    Operating Range, High Limit (F): 120 F to 240 F
    Operating Range, High Limit (C): 54 C to 116 C
    Differential Temperature (F): 8 F fixed
    Setpoint Temperature Range (F): 240 F
    Setpoint Temperature Range (C): 116 C
    Switching Action: SPST: High Limit & Circulator
    Anticipator Setting: 0.2 A
    Maximum Operating Pressure (psi): Immersion Well: 255 psi
    Maximum Operating Pressure (kPa): Immersion Well: 1757 kPa
    Electrical Ratings (burner AFL): Line Voltage: 7.4 A @ 120 Vac; 3.7 A @ 240 Vac
    Electrical Ratings (burner ALR): Line Voltage: 44.4 A @ 120 Vac; 22.7 A @ 240 Vac
    Electrical Ratings (burner millivolt): 0.25 A @ 1/4 to 12 Vdc
    Electrical Ratings (circulator AFL): 7.4 A @ 120 Vac
    Electrical Ratings (circulator AFL): 3.7 A @ 240 Vac
    Electrical Ratings (circulator ALR): 44.4 A @ 120 Vac
    Electrical Ratings (circulator ALR): 22.2 A @ 240 Vac
    Voltage: 120 Vac
    Frequency: 60 Hz
    Capillary Length (in.): 4 1/2 in.
    Capillary Length (mm): 114 mm
    Dimensions (in.): 4 5/16 in. high x 6 1/8 in. wide x 3 1/8 in. deep
    Dimensions (mm): 110 mm high x 156 mm wide x 79 mm deep
    Insulation Depth (in.): 1 1/2 in. to 3 in. less well.
    Insulation Depth (mm): 38 mm to 76 mm less well
    Mounting: Horizontal
    Operating Humidity Range (% RH): 0 to 95% RH, non-condensing
    Maximum Ambient Temperature (F): 150 F with 1.2 A 24 V load; 77 F with 1.4 A 24 V load
    Maximum Ambient Temperature (C): 66 C with 1.2 A 24 V load; 25 C with 1.4 A 24 V load
    Electrical Connections : Quick-Connect / Screw
    Approvals, Underwriters Laboratories Inc : UL Listed: File No. MP466, Vol. 13, Sec. 2, Guide No. MBPR2.
    Approvals, Canadian Standards Association: Certified: File No. LR1620, Guide No. 400-E-O
    Tradeline Value : Tradeline

    High Limit Horizontal Mount Aquastat Relay, 8°F differential

    REVIEW SNAPSHOT®

    by PowerReviews
    HoneywellHigh Limit Horizontal Mount Aquastat Relay, 8°F differential
     
    4.7

    (based on 7 reviews)

    Ratings Distribution

    • 5 Stars

       

      (5)

    • 4 Stars

       

      (2)

    • 3 Stars

       

      (0)

    • 2 Stars

       

      (0)

    • 1 Stars

       

      (0)

    100%

    of respondents would recommend this to a friend.

    Pros

      Cons

        Best Uses

            • Primary use:
            • Personal (6)

          Reviewed by 7 customers

          Sort by

          Displaying reviews 1-7

          Back to top

           
          4.0

          Hooray for Pex Supply

          By Jim

          from Northern NY

          Verified Buyer

          Pros

            Cons

              Best Uses

                Comments about High Limit Horizontal Mount Aquastat Relay, 8°F differential:

                OK, what does one say about an aquastat, especially a Honeywell. They do the job well and have a reasonably acceptable design life. Now with Pex Supply in the game, it is also possible to purchase this type of product for a fair price.

                Thank you Pex Supply,
                Jim

                • Primary use:
                • Business
                 
                5.0

                Successful swap

                By Jack

                from Waterbury VT

                Verified Buyer

                Pros

                  Cons

                    Best Uses

                      Comments about High Limit Horizontal Mount Aquastat Relay, 8°F differential:

                      This was a refit for worn out Aquastat on my 10 year old boiler. the fit and electrical connections were perfect. The kit was complete right down to the heat transfer paste for the sensor. while the part numbers were not identical this unit was as close to a one for one match as I coulde hope for.

                      • Primary use:
                      • Personal
                       
                      5.0

                      Just what I needed!

                      By Jamie

                      from Annandale, VA

                      Verified Buyer

                      Pros

                        Cons

                          Best Uses

                            Comments about High Limit Horizontal Mount Aquastat Relay, 8°F differential:

                            I couldn't find much info on troubleshooting my old relay. I didn't want to spend over $100 on something I didn't need but when I wasn't getting any output voltage on the burner side of the relay I had no other option but to order a new relay and hope that was the issue. PEXSupply delivered the relay as advertised and it fixed the problem. Easy fix and cheaper then paying a tech at least $100 just to tell you the issue.

                            • Primary use:
                            • Personal
                             
                            5.0

                            I would by this controller again

                            By lover

                            from Blackstone, IL.

                            Verified Buyer

                            Pros

                              Cons

                                Best Uses

                                  Comments about High Limit Horizontal Mount Aquastat Relay, 8°F differential:

                                  I use this product to control my oil burner

                                  • Primary use:
                                  • Personal
                                   
                                  4.0

                                  No problems

                                  By DIY

                                  from Marshall, VA

                                  Verified Buyer

                                  Pros

                                    Cons

                                      Best Uses

                                        Comments about High Limit Horizontal Mount Aquastat Relay, 8°F differential:

                                        Quick delivery, clear instructions, easy installation, works fine.

                                        • Primary use:
                                        • Personal
                                         
                                        5.0

                                        ...

                                        By BG

                                        from seattle, WA

                                        Verified Buyer

                                        Pros

                                          Cons

                                            Best Uses

                                              Comments about High Limit Horizontal Mount Aquastat Relay, 8°F differential:

                                              The controller was exactly as stated. Works great and Pex has the best price.

                                              • Primary use:
                                              • Personal
                                               
                                              5.0

                                              Once again

                                              By Jim

                                              from NY

                                              Verified Buyer

                                              Pros

                                                Cons

                                                  Best Uses

                                                    Comments about High Limit Horizontal Mount Aquastat Relay, 8°F differential:

                                                    [...] What can you say about a honeywell relay - it does what it is meant to do.

                                                    • Primary use:
                                                    • Personal

                                                    Displaying reviews 1-7

                                                    Back to top

                                                    Q&A: Ask the Questions, share answers

                                                    Do you have questions about this product?

                                                    get answers from real customers and in-house experts with AnswerBox.

                                                    8 Questions | 9 Answers
                                                    Displaying questions 1-8
                                                    • High Limit Horizontal Mount Aquastat Relay, 8°F differential

                                                      Q:

                                                      can i replace L8148j with L8148a model
                                                      Asked on 1/25/2012 by Anonymous

                                                      1 answer

                                                      • CUSTOMER CARE

                                                        A:

                                                        Maybe, depending on what you're using it for. L8148A1017 is a high limit aquastat that can only be mounted horizontally. L8148J1009 is an aquastat relay that can be mounted either horizontally or vertically.

                                                        Answered on 1/26/2012 by PexSupply Staff from NY
                                                    • High Limit Horizontal Mount Aquastat Relay, 8°F differential

                                                      Q:

                                                      zone valves are calling boiler fires but pump not running. put new pum[p on still not running tested pump with ciord and it works.is it the aquastat???
                                                      Asked on 1/18/2012 by Anonymous

                                                      1 answer

                                                      • CUSTOMER CARE

                                                        A:

                                                        It is likely an issue with the aquastat. It could also be a problem with the actual wires.

                                                        Answered on 1/19/2012 by PexSupply Staff from NY
                                                    • High Limit Horizontal Mount Aquastat Relay, 8°F differential

                                                      Q:

                                                      Can I Substitute a Honeywell L8148A 1157 Aquastat Relay for a L8148A 1090. Is a 1157 still available ?
                                                      Asked on 8/10/2011 by Anonymous

                                                      2 answers

                                                      • CUSTOMER CARE

                                                        A:

                                                        Both those items are obsolete and can be replaced by part L7224U1002. L8148A1090 can also be replaced by L8148A1017.

                                                        Answered on 8/10/2011 by PexSupply Staff from NY
                                                      • VERIFIED BUYER

                                                        A:

                                                        I am not a heating pro. I would compare the electrical rating on each unit and the layout- horizontal/ Vertical. My swap had different 4 digit end numbers in the id and the match was perfect mechanically and electrically. The part # L8148A were matching on both units.

                                                        Answered on 1/17/2012 by Jack from Waterbury VT
                                                    • High Limit Horizontal Mount Aquastat Relay, 8°F differential

                                                      Q:

                                                      Can I substitute a L8148A 1017 Aquastat Relay for a L8148A 1090 ?
                                                      Asked on 8/7/2011 by Anonymous

                                                      1 answer

                                                      • CUSTOMER CARE

                                                        A:

                                                        Yes, you can.

                                                        Answered on 8/8/2011 by PexSupply Staff from NY
                                                    • High Limit Horizontal Mount Aquastat Relay, 8°F differential

                                                      Q:

                                                      WHAT SIZE WELL DOES THIS AQUASTAT NEED LONG OR SHORT
                                                      Asked on 6/7/2011 by DAN from UPSTATE NY

                                                      1 answer

                                                      • CUSTOMER CARE

                                                        A:

                                                        If you are speaking of the insulation depth, the L8148 may be used with either the 1-1/2” or 3” model wells. These instructions are located on a label attached to the back of the control.

                                                        Answered on 6/8/2011 by PexSupply Staff from NY
                                                    • High Limit Horizontal Mount Aquastat Relay, 8°F differential

                                                      Q:

                                                      I have a Honeywell Aquastat model L8148a-1157 Vertical mounted. What is the replacement model number for this part?
                                                      Asked on 6/5/2011 by Anonymous

                                                      1 answer

                                                      • CUSTOMER CARE

                                                        A:

                                                        The manufacturer lists part L7224U1002 as the replacement for L8148A1157.

                                                        Answered on 6/6/2011 by PexSupply Staff from NY
                                                    • High Limit Horizontal Mount Aquastat Relay, 8°F differential

                                                      Q:

                                                      I have the L8148A1017 on my boiler. The switching relay provides voltage to the boiler but not the circulator. Should I replace the whole thing or can I just change out the relay itself?
                                                      Asked on 1/3/2011 by John the surfer

                                                      1 answer

                                                      • CUSTOMER CARE

                                                        A:

                                                        To ensure proper operation, we recommend replacing the entire model.

                                                        Answered on 1/14/2011 by PexSupply Staff from NY
                                                    • High Limit Horizontal Mount Aquastat Relay, 8°F differential

                                                      Q:

                                                      i would like to replace my honeywell aquastat #l8148a on my oil furnace but i noticed that your product replacement is #l8148a1017.does the 1017 number matter?
                                                      Asked on 12/12/2010 by Anonymous from york,maine

                                                      1 answer

                                                      • CUSTOMER CARE

                                                        A:

                                                        No, the last 4 digits do not matter. This would be an appropriate replacement.

                                                        Answered on 12/15/2010 by PexSupply Staff from NY
                                                    Displaying questions 1-8

                                                    Do you have a question about this product? 

                                                    PexSupply.com Logo

                                                    Join Our Mailing List - Sign up and receive special offers and coupons

                                                    Nextag Seller PriceGrabber User Ratings for Pex Supply PHCC BBB Reliability Seal
                                                    HACKER SAFE certified sites prevent over 99.9% of hacker crime. Facebook Twitter Youtube