Specs

Application: High Limit
Switch Action: SPST
Electrical Rating: Burner: 0.8 A max @ 24 Vac
Burner: 3.7 A @ 240 Vac
Burner: 7.4 A @ 120 Vac
Circulator: 3.7 A @ 240 Vac
Circulator: 7.4 A @ 120 Vac
0.25 A @ 0.25 to 12 Vdc
Electrical Ratings (ALR): Circulator: 44.4 A @ 120 Vac
Burner: 44.4 A @ 120 Vac
Circulator: 22.2 A @ 240 Vac
Burner: 22.2 A @ 240 Vac
Max Temp Differential: 15°F
Differential:
?
Fixed
Height: 6-1/8"
Width: 4-3/8"
Depth (Inches): 3-1/8"
Operating Humidity: 0% to 95% (non-condensing)
Mount: Vertical
Max Ambient Temp (°F): 150F with 1.2A 24V Load
77F with 1.4A 24V Load
Connection Type: Quick-Connect
Capillary Length: 4-1/2"
Anticipator Rating: 0.2 A
Voltage:
?
120v
Frequency: 60 Hz
Max Pressure (PSI): 255 psi @ Immersion Well
Max Temp (F): 240°F
Min Temp (F): 180°F
Temperature Range (F): 180°F to 240°F

Description for Honeywell L8148E1299

Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors.
Features

  • High limit opens burner circuit only.
  • Include transformer and accessory terminals for adding a remote low limit controller.
  • Case available for horizontal or vertical mounting.
  • Requires a 24 Vac thermostat with heat anticipator set at 0.2A.
  • TRADELINE models include well adapter and range stops.

  • Product Specifications
    Description :High Limit Aquastat Relay with 15 F fixed differential
    Application :High Limit
    Operating Range, High Limit (F) : 180 F to 240 F
    Operating Range, High Limit (C) : 54 C to 116 C
    Differential Temperature (F) : 15 F fixed
    Switching Action : SPST: High Limit & Circulator
    Anticipator Setting : 0.2 A
    Maximum Operating Pressure (psi) : Immersion Well: 255 psi
    Maximum Operating Pressure (kPa) : Immersion Well: 1757 kPa
    Electrical Ratings (ALR) : 44.4A @ 120 Vac
    Electrical Ratings (ALR) : 22.2A @ 240 Vac
    Electrical Ratings : 0.25 A @ 0.25 to 12 Vdc
    Electrical Ratings (burner AFL) : Line Voltage: 7.4 A @ 120 Vac; 3.7 A @ 240 Vac
    Electrical Ratings (burner AFL) : Low Voltage: 0.8 A max. @ 24 Vac
    Electrical Ratings (burner ALR) : Line Voltage: 44.4 A @ 120 Vac; 22.7 A @ 240 Vac
    Electrical Ratings (burner millivolt) : 0.25 A @ 1/4 to 12 Vdc
    Electrical Ratings (circulator AFL) : 3.7 A @ 240 Vac
    Electrical Ratings (circulator AFL) : 7.4 A @ 120 Vac
    Electrical Ratings (circulator ALR) : 44.4 A @ 120 Vac
    Electrical Ratings (circulator ALR) : 22.7 A @ 240 Vac
    Voltage : 120 Vac
    Frequency : 60 Hz
    Capillary Length (in.) : 4 1/2 in.
    Capillary Length (mm) : 114 mm
    Dimensions (in.) : 6 1/8 in. high x 4 5/16 in. wide x 3 1/8 in. deep
    Dimensions (mm) : 156 mm high x 110 mm wide x 79 mm deep
    Insulation Depth (in.) : 1 1/2 in. to 3 in. less well.
    Insulation Depth (mm) : 38 mm to 76 mm less well
    Mounting : Vertical Mount
    Operating Humidity Range (% RH) : 0 to 95% RH, non-condensing
    Maximum Ambient Temperature (F) : 150 F with 1.2 A 24 V load; 77 F with 1.4 A 24 V load
    Maximum Ambient Temperature (C) : 66 C with 1.2 A 24 V load; 25 C with 1.4 A 24 V load
    Electrical Connections : Quick-Connect / Screw
    Approvals, Underwriters Laboratories Inc : UL Listed: File No. MP466, Vol. 13, Sec. 2, Guide No. MBPR2.
    Approvals, Canadian Standards Association : Certified: File No. LR95329-1
    Includes : 50 VA transformer