Lockout Timing: 45 Seconds

Description for Honeywell R8184G4009

Provides automatic, nonrecycling control of an intermittent ignition oil burner system.

Specifications

  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat.
  • Solid state flame sensing circuit.
  • LED on terminal strip indicates system lockout.
  • Remote lockout indication available on some models.
  • Enclosed safety switch with external reset button.
  • Manual trip lever opens safety switch for system maintenance.
  • Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing.
  • C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required.


Features
  • Description: Protectorelay Oil Burner Control with 45 seconds lock out timing
  • Ignition Type: Intermittent
  • Timing, Safety Switch: 45 sec.
  • Mounting Bracket: For mounting on a standard 4 in. X 4 in. junction box or direct mounting on burner housing.
  • Electrical Ratings (Full Load): 7.4 A @ 120 Vac; 3.7 a @ 240 Vac
  • Electrical Ratings (Locked Rotor): 44.4 A @ 120 Vac; 22.2 A @ 240 Vac
  • Alarm Load Ratings (Pilot Duty): 75 VA @ 120/240 Vac, 50-60 Hz; 25 VA @ 24V, 50-60 Hz
  • Alarm Load Ratings (resistive): 1.5 A @ 120/240V, 50-60Hz; 3 A @ 24 V, 50-60 Hz
  • Dimensions: 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep
  • Temperature Range: -40 F to +130 F
  • Comments: With LED for lockout indication, and manual trip lever on safety switch to assure burner shutdown during servicing.

Protectorelay Oil Burner Control with 45 seconds lock out timing

REVIEW SNAPSHOT®

by PowerReviews
Honeywell Protectorelay Oil Burner Control with 45 seconds lock out timing
 
4.8

(based on 4 reviews)

Ratings Distribution

  • 5 Stars

     

    (3)

  • 4 Stars

     

    (1)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (0)

100%

of respondents would recommend this to a friend.

Reviewed by 4 customers

Sort by

Displaying reviews 1-4

Back to top

 
4.0

Great Product

By Just a guy

from Seattle, Wa

Verified Buyer

Pros

    Cons

      Best Uses

        Comments about Honeywell Protectorelay Oil Burner Control with 45 seconds lock out timing:

        Great product, quick delivery and install, did the trick!

        • Primary use:
        • Personal
         
        5.0

        even a person from odin can install it

        By bucky fox

        from austin pa

        Verified Buyer

        Pros

          Cons

            Best Uses

              Comments about Honeywell Protectorelay Oil Burner Control with 45 seconds lock out timing:

              fit like they said

              • Primary use:
              • Personal
               
              5.0

              Worked as expected and easy to install

              By Kidddrock

              from Richmond, VA

              Verified Buyer

              Comments about Honeywell Protectorelay Oil Burner Control with 45 seconds lock out timing:

              When I diagnosed a safety switch issue on my oil furnace I shopped around and found this item for a good price [...]. It was easy to install and had heat with thermostat control within about an hour (a professionaly probably would have only taken about 20 minutes). Works great and love the ability to manually trip the switch to test it - my previous one didn't have that feature.

               
              5.0

              I would buy this product again and again

              By kcl1957

              from ERIE PA

              Verified Buyer

              Comments about Honeywell Protectorelay Oil Burner Control with 45 seconds lock out timing:

              Installation instructions easily understood.

              Displaying reviews 1-4

              Back to top

              Q&A: Ask the Questions, share answers

              Do you have questions about this product?

              get answers from real customers and in-house experts with AnswerBox.

              1 Question | 1 Answer
              Displaying question 1
              • Honeywell Protectorelay Oil Burner Control with 45 seconds lock out timing

                Q:

                how to bleed the fuel line from air. Because the furnace lights but keeps going out wont stay on. Please help ¡
                Asked on 1/12/2012 by Jessica from Or

                1 answer

                • CUSTOMER CARE

                  A:

                  Normally there is a bleed valve on the burner or oil pump.

                  Answered on 1/13/2012 by PexSupply Staff from NY
              Displaying question 1

              Do you have a question about this product? 

              PexSupply.com Logo

              Join Our Mailing List - Sign up and receive special offers and coupons

              Nextag Seller PriceGrabber User Ratings for Pex Supply PHCC BBB Reliability Seal
              HACKER SAFE certified sites prevent over 99.9% of hacker crime. Facebook Twitter Youtube