Description for Robertshaw 780-845

When the thermostat calls for heat, the 780-845 control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. Pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. Pilot burner flame is continuously monitored at a synchronous frequency for the duration of the heating cycle. Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is established.
The 780-845 lockout ignition control provides 90 seconds of spark, followed by a 6 minute time delay (purge) between ignition attempts. After three tries, if no pilot flame is sensed, the control goes into a one-hour lockout period. At the end of the lockout period, if the demand for heat is still present, the unit will repeat the three tries for ignition.
During lockout, you may override the auto-system, and manually reset the unit at the thermostat. The green diagnostic LED will be on continuously for normal operation. The LED will be off for internal lockout and will flash continuously for problems external to the control (ie. not sensing flame).
Specifications

    Input Voltage: 24 VAC to 50/60 Hz
    Transformer: 24 VAC / 20 VA
    Safety lockout timing: 90 seconds
    Spark rate: 4 to 15 sparks per second
    Pilot valve, Main valve: 1 amp at .5 PF
    Combined load: 1.5 at .4 PF
    Flame sense current: .7 mA DC @ 25°C / 24 VAC
    Maximum total current load: 1.5 amp
    Flame failure reignition time: 2 seconds maximum
    Ambient temperature rating: –40 to 175° (–40 to 80°C)
    Relative humidity: 95% noncondensing at 104°F
    Factory Model # SP845 (SP 845) 100-00834-41

Universal Intermittent Pilot Lockout Ignition Module

REVIEW SNAPSHOT®

by PowerReviews
RobertshawUniversal Intermittent Pilot Lockout Ignition Module
 
4.9

(based on 10 reviews)

Ratings Distribution

  • 5 Stars

     

    (9)

  • 4 Stars

     

    (1)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (0)

100%

of respondents would recommend this to a friend.

Pros

    Cons

      Best Uses

          • Primary use:
          • Personal (7), Business (3)

        Reviewed by 10 customers

        Sort by

        Displaying reviews 1-10

        Back to top

         
        5.0

        Great replacement for SP-745

        By Jeff

        from Salt Lake City, UT

        Verified Buyer

        Pros

          Cons

            Best Uses

              Comments about Universal Intermittent Pilot Lockout Ignition Module:

              I used this to replace my failing SP-745 control module on my Lennox furnace. It worked perfectly. All the connections matched up (just in a different order, so make sure you keep the old one around for reference while installing). There was one wire (a ground on the old one) that was not required for the replacement installation, but other than that it was a perfect match. Having the LED on there for status is a nice extra. For installation, the only big difference between this and the original is that the original controller had some mounting holes that were not on this unit. Mine was attached to a plate using mounting those holes originally, so I used some industrial strength velcro to mount it instead - it'll make any future de-install a little easier).

              • Primary use:
              • Personal
               
              5.0

              simply outstanding service

              By Batman

              from Ontario, Canada

              Verified Buyer

              Pros

                Cons

                  Best Uses

                    Comments about Universal Intermittent Pilot Lockout Ignition Module:

                    Middle of winter and my furnace went down. Located the part on Pexsupply and had it my hands the next day. Simply outstanding service and delivery. Very pleased...I can guarantee I will be shopping here again.

                    • Primary use:
                    • Business
                     
                    5.0

                    It works

                    By Handy

                    from Fort Collins, CO

                    Verified Buyer

                    Pros

                      Cons

                        Best Uses

                          Comments about Universal Intermittent Pilot Lockout Ignition Module:

                          Replaced the controller in my Lennox G16 furnace. No more problems. PEX had a great price.
                          **NOT PEX's fault**, but my shipment sat for 5 days at the UPS terminal in NJ 8( - meanwhile my furnace was intermittant.

                          • Primary use:
                          • Personal
                           
                          5.0

                          Great replacement for Robertshaw SP 745

                          By Tony Johnston

                          from Pauls Valley Oklahoma

                          Verified Buyer

                          Pros

                            Cons

                              Best Uses

                                Comments about Universal Intermittent Pilot Lockout Ignition Module:

                                At about $100.00 dollars less than the Robertshaw Sp 745 this replacement works great. I installed it to my furnace in less than 10 minutes and became my wifes hero. This model replaces Sp745 in any application, cost less and is a easy DIY anyone with a screwdriver can do it. Just remember to turn off the gas and unplug the unit. Happy heating!!!

                                • Primary use:
                                • Personal
                                 
                                5.0

                                "Great Replacement, half the price"

                                By Mr. & Mrs. Wgglewrm

                                from Crystal City, MO

                                Verified Buyer

                                Pros

                                  Cons

                                    Best Uses

                                      Comments about Universal Intermittent Pilot Lockout Ignition Module:

                                      When it got cold, our Furnace would not kick on. My husband used the schematic that came with the furnace and traced the problem to The pilot lockout module. We searched locally for the part and then online. Pex had the part at half the cost of anyone else. We had to wait a few days for it, but that was fine. My husband was able to easily install it and our Furnace works like new. Thank You Pex.

                                      • Primary use:
                                      • Personal
                                       
                                      5.0

                                      It works great

                                      By Kw

                                      from Leona. Valley

                                      Verified Buyer

                                      Pros

                                        Cons

                                          Best Uses

                                            Comments about Universal Intermittent Pilot Lockout Ignition Module:

                                            Quick to replace old one

                                            • Primary use:
                                            • Personal

                                            (1 of 1 customers found this review helpful)

                                             
                                            5.0

                                            Perfect Drop-in Replacement

                                            By Dad the repair man

                                            from Boise, ID

                                            Verified Buyer

                                            Pros

                                              Cons

                                                Best Uses

                                                  Comments about Universal Intermittent Pilot Lockout Ignition Module:

                                                  I started the day with a cold shower... My power vent gas water heater stopped working. Visual inspection showed that there was ignition spark, but no flame. A DMM on the controller terminals for the primary gas valve showed that the old controller was never putting out the 24V signal to turn on the gas to the main burner.

                                                  I called around the local plumbers and suppliers. They didn't have the part and wanted to replace the water heater for $2500 and a three day wait. Yikes!

                                                  I knew about PexSupply.com from researching a radiant heat project. Their web site showed the part in stock, but it was getting late in the day and I needed to be sure to get hot water flowing ASAP, so I called. The lady that took my order was very helpful. She made sure my part got out that day. It arrived at 9:30 AM the next morning. Ten minutes later, we were making hot water and I was the hero.

                                                  Thanks PexSupply.com!

                                                  • Primary use:
                                                  • Personal
                                                   
                                                  5.0

                                                  great product

                                                  By walipro

                                                  from stevens point wi

                                                  Verified Buyer

                                                  Pros

                                                    Cons

                                                      Best Uses

                                                        Comments about Universal Intermittent Pilot Lockout Ignition Module:

                                                        great product easy to use

                                                        • Primary use:
                                                        • Business
                                                         
                                                        5.0

                                                        Reliable controller

                                                        By Modela Negra

                                                        from Santa Rosa

                                                        Verified Buyer

                                                        Pros

                                                          Cons

                                                            Best Uses

                                                              Comments about Universal Intermittent Pilot Lockout Ignition Module:

                                                              This is an replacement controller that is easily installed. All terminals are clearly identified and the controller can be configured for a couple of variations.

                                                              • Primary use:
                                                              • Business
                                                               
                                                              4.0

                                                              Is working as expected

                                                              By jan

                                                              from Indiana

                                                              Verified Buyer

                                                              Pros

                                                                Cons

                                                                  Best Uses

                                                                    Comments about Universal Intermittent Pilot Lockout Ignition Module:

                                                                    I placed it on my water heater and it worked right out of the box as I expected it to do. It's kind of one of those things that either works or doesn't.

                                                                    • Primary use:
                                                                    • Personal

                                                                    Displaying reviews 1-10

                                                                    Back to top

                                                                    Q&A: Ask the Questions, share answers

                                                                    Do you have questions about this product?

                                                                    get answers from real customers and in-house experts with AnswerBox.

                                                                    11 Questions | 12 Answers
                                                                    Displaying questions 1-10Previous | Next »
                                                                    • Universal Intermittent Pilot Lockout Ignition Module

                                                                      Q:

                                                                      does this require a sense feed back? I just bought this product and the pilot is on but not being sensed. The model i replaced is a sp745 with no sense terminal.
                                                                      Asked on 3/14/2012 by Anonymous

                                                                      1 answer

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        Part 780-845 is the functional replacement for the Robertshaw SP745. If the spark isn't being sensed, there may be a wiring issue.

                                                                        Answered on 3/15/2012 by PexSupply Staff from NY
                                                                    • Universal Intermittent Pilot Lockout Ignition Module

                                                                      Q:

                                                                      Does this replace model No. DS 845 NL-1-4
                                                                      Asked on 2/29/2012 by Anonymous

                                                                      1 answer

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        No, part 780-502 is actually the recommended replacement for the obsolete DS845-NL-1-4.

                                                                        Answered on 3/1/2012 by PexSupply Staff from NY
                                                                    • Universal Intermittent Pilot Lockout Ignition Module

                                                                      Q:

                                                                      Does this replace the Lennox SP745? I don't see the IGN part after the sense.

                                                                      Thanks!
                                                                      Asked on 10/1/2011 by Anonymous

                                                                      2 answers

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        Yes, 780-845 is the listed replacement for SP745.

                                                                        Answered on 10/3/2011 by PexSupply Staff from NY
                                                                      • VERIFIED BUYER

                                                                        A:

                                                                        Yes it absolutely does. I replaced my Robertshaw Sp 745 with this unit and it worked perfect. Just pay close attention when you attach those leads. The IGN is attached on top of the new unit and one of your wires from the old unit no longer needs to be hooked up. I did mine side by side and had no trouble. Take a picture of how it was originaly wired for reference. If you dont get a spark you did it wrong. Make sure gas and elec is off during install. Happy heating!!! Oh yea it cost less than the original, WOW

                                                                        Answered on 12/22/2011 by Tony Johnston from Pauls Valley Oklahoma
                                                                    • Universal Intermittent Pilot Lockout Ignition Module

                                                                      Q:

                                                                      I have an Omega radiant heater with a Robertshaw module model # DS-845 PR-3-7 that needs to be replaced what is the replacement part # ? Thanks.
                                                                      Asked on 4/16/2011 by Sparke

                                                                      1 answer

                                                                    • Universal Intermittent Pilot Lockout Ignition Module

                                                                      Q:

                                                                      WILL THIS MODEL REPLACE A ROBERTSHAW MODEL SP735L IGNATOR???
                                                                      Asked on 4/1/2011 by DOUG from LEXINGTON, KY

                                                                      1 answer

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        The replacements for the SP735L ignitor are 780-002 or 780-845.

                                                                        Answered on 4/5/2011 by PexSupply Staff from NY
                                                                    • Universal Intermittent Pilot Lockout Ignition Module

                                                                      Q:

                                                                      my propane furnace has a broken Robertshaw lockout module, sp715/sp715a or 018-00080. Is the cross number 780-845? If not what one is?
                                                                      Asked on 3/25/2011 by Glenn from Redding,CA

                                                                      1 answer

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        The replacement for that unit is 780-715.

                                                                        Answered on 3/29/2011 by PexSupply Staff from NY
                                                                    • Universal Intermittent Pilot Lockout Ignition Module

                                                                      Q:

                                                                      I have a Heatilator fireplace (GC-300) that uses the DS845 ignition module. The module needs to be replaced. Heatilator Customer Service told me to use the Robertshaw 15695A module. When cross referencing this part I came up with a variety of numbers such as IGM 780-845A. Your staff replied on 2/3/11 that this is not the correct replacement part. What is the correct replacement part to use?
                                                                      Asked on 3/15/2011 by Ken from O'fallon, MO

                                                                      1 answer

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        According to the manufacturer, 780-501, 780-502, 780-503, and 780-504 are the replacements for the DS845. The one you need depends on the entire model number (i.e. what comes after 'DS845'). You may want to check with Heatilator on whether or not this was an OEM part.

                                                                        Answered on 3/16/2011 by PexSupply Staff from NY
                                                                    • Universal Intermittent Pilot Lockout Ignition Module

                                                                      Q:

                                                                      will this replace a robertshaw sp745?
                                                                      Asked on 3/9/2011 by stugots from buffalo, NY

                                                                      1 answer

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        Yes, it will.

                                                                        Answered on 3/9/2011 by PexSupply Staff from NY
                                                                    • Universal Intermittent Pilot Lockout Ignition Module

                                                                      Q:

                                                                      Is this the replacement for a Robertshaw DS845 controller?
                                                                      Asked on 1/23/2011 by Chris

                                                                      1 answer

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        It is not. You need to use a 780-501, 780-502, 780-503, or 780-504.

                                                                        Answered on 2/3/2011 by PexSupply Staff from NY
                                                                    • Universal Intermittent Pilot Lockout Ignition Module

                                                                      Q:

                                                                      is this module for LP
                                                                      Asked on 10/21/2010 by DJ from topeka ,KS

                                                                      1 answer

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        It is. It can be used for either propane or natural gas. The gas valves that will be connected in the system will have to be fuel specific.

                                                                        Answered on 11/5/2010 by PexSupply Staff from NY
                                                                    Displaying questions 1-10Previous | Next »

                                                                    Do you have a question about this product? 

                                                                    PexSupply.com Logo

                                                                    Join Our Mailing List - Sign up and receive special offers and coupons

                                                                    Nextag Seller PriceGrabber User Ratings for Pex Supply PHCC BBB Reliability Seal
                                                                    HACKER SAFE certified sites prevent over 99.9% of hacker crime. Facebook Twitter Youtube