Boiler Control - One Stage Boiler Zoom

Boiler Control - One Stage Boiler

SKU:256

Brand: Tekmar

Tekmar
Qty Price
$154.95
/ each
In Stock! Ships in 24-48 Hours
33 Available

Specs

Application: Single Boiler
Stages:
?
1
Width: 2-7/8"
Height: 4-3/4"
User Interface: Push Button
LCD
Voltage:
?
24v
Depth: 7/8"
Ambient Conditions: Indoor Only: 32°-104°F < 90% RH non-condensing
Power Supply: Class 2
24 V (ac)
Relays: 240 V (ac) 5 A-1/6 hp
Temperature Range (F): -60°-266°F
Control: Microprocessor PID control
Weight: 1.3 lbs
Demands: 24 V (ac) 2 VA
Sensors: NTC Thermistor
10 k ohm @ 77°F

Description for Tekmar 256


The Tekmar 256 Boiler Control is a microprocessor-based control designed to regulate the supply water temperature from a single boiler based on the outdoor temperature. To avoid boiler short cycling and large temperature swings, the 256 is able to continuously adjust the boiler differential. The Tekmar 256 includes control functions such as Warm Weather Shut Down (WWSD) and Minimum Boiler setting. The control has a liquid crystal display (LCD) that normally displays the Boiler Supply temperature, but can display other temperatures and settings.
Tekmar 256 Specifications:
Literature: D 256, A 256's, D 001, D 070
Control: Microprocessor PID control; This is not a safety (limit) control
Packaged Weight: 1.3 lb. (580 g), Enclosure C, white PVC plastic
Dimensions: 4-3/4" H x 2-7/8" W x 7/8" D (120 x 74 x 22 mm)
Approvals: CSA C US, meets ICES & FCC regulations for EMI/RFI
Ambient Conditions: Indoor use only, 32 to 104+F (0 to 40+C), < 90% RH non-condensing
Power Supply: 24 V +10% 50/60 Hz 3 VA
Relay: 240 V (ac) 5 A 1/6 hp, pilot duty 240 VA
Demand: 24 V (ac) 2 VA
Sensors Included: NTC thermistor, 10 kW @ 77+F (25+C +0.2+C) +=3892 Outdoor Sensor 070 & Universal Sensor 071
Optional Devices: Tekmar type #: 031, 032

Boiler Control - One Stage Boiler

REVIEW SNAPSHOT®

by PowerReviews
Tekmar Boiler Control - One Stage Boiler
 
4.4

(based on 9 reviews)

Ratings Distribution

  • 5 Stars

     

    (7)

  • 4 Stars

     

    (1)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (1)

89%

of respondents would recommend this to a friend.

Pros

    Cons

      Best Uses

          • Primary use:
          • Personal (5), Business (4)

        Reviewed by 9 customers

        Sort by

        Displaying reviews 1-9

        Back to top

         
        5.0

        Tekmar

        By williamsfixit

        from Ma

        Verified Buyer

        Pros

          Cons

            Best Uses

              Comments about Tekmar Boiler Control - One Stage Boiler:

              This is worth your money .Istalls easy and fast set up too MUST FOR oil heating systems

              • Primary use:
              • Business

              (0 of 1 customers found this review helpful)

               
              5.0

              WHAT EVERY HW BOILER SHOULD HAVE

              By MASTER PLUMBER ANT

              from HARRISON N.Y.

              Verified Buyer

              Pros

                Cons

                  Best Uses

                    Comments about Tekmar Boiler Control - One Stage Boiler:

                    if you have a hot water boiler this control should be installed for 10-20% energy savings.note needs to be installed by qualified personal

                    • Primary use:
                    • Business

                    (1 of 1 customers found this review helpful)

                     
                    5.0

                    great product

                    By red machine

                    from elma n.y.

                    Verified Buyer

                    Pros

                      Cons

                        Best Uses

                          Comments about Tekmar Boiler Control - One Stage Boiler:

                          this is so easy to hook up

                          • Primary use:
                          • Personal
                           
                          5.0

                          Energy savings!

                          By Go Steelers!!!

                          from Pittsburgh Pa

                          Verified Buyer

                          Pros

                            Cons

                              Best Uses

                                Comments about Tekmar Boiler Control - One Stage Boiler:

                                Added feature to any boiler installation

                                • Primary use:
                                • Business
                                 
                                5.0

                                excellant boiler control

                                By atul

                                from ontario, canada

                                Verified Buyer

                                Pros

                                  Cons

                                    Best Uses

                                      Comments about Tekmar Boiler Control - One Stage Boiler:

                                      i bouight Tekmar 256 to replace my old Honeywell T475A 1032 outdoor reset controller. I made right choice. New Tekmar 256 woks better than my old honeywell. If you would like to control just your boiler On/off based on outdoor reset, All u need Tekmar 256. Very easy to install.

                                      • Primary use:
                                      • Personal
                                       
                                      5.0

                                      33% fuel savings!

                                      By Ian

                                      from Rochester, NY

                                      Verified Reviewer

                                      Pros

                                        Cons

                                          Best Uses

                                            Comments about Tekmar Boiler Control - One Stage Boiler:

                                            This unit is some what of a difficult install, requiring the use of an external relay and power supply in my situation. However, according to the past few months utility bills I've been using 1-2 therms LESS per day with an average daily temperature of 1-2 degrees COLDER than last year, and I'm running the exact same settings on my programmable thermostat.

                                            I am impressed.

                                            • Primary use:
                                            • Personal

                                            (1 of 1 customers found this review helpful)

                                             
                                            5.0

                                            Fast easy and yes it works A+

                                            By jaws

                                            from mass

                                            Verified Buyer

                                            Pros

                                              Cons

                                                Best Uses

                                                  Comments about Tekmar Boiler Control - One Stage Boiler:

                                                  with an indirect water tank form heating supply
                                                  fast to install
                                                  If you have big hands like me it might be a little hard to wire but its worth the time

                                                  • Primary use:
                                                  • Business

                                                  (1 of 1 customers found this review helpful)

                                                   
                                                  4.0

                                                  Good product; reasonably priced

                                                  By Dan

                                                  from Goldens Bridge, NY

                                                  Verified Buyer

                                                  Pros

                                                    Cons

                                                      Best Uses

                                                        Comments about Tekmar Boiler Control - One Stage Boiler:

                                                        I bought this unit last fall to provide boiler reset on a very old (approx. 70 years) oil fired boiler feeding baseboard heat. I custom fitted the installation to match my system parameters, and it has worked perfectly since installed. Hope to save some oil with it.

                                                        • Primary use:
                                                        • Personal

                                                        (1 of 2 customers found this review helpful)

                                                         
                                                        1.0

                                                        not very good

                                                        By jerry

                                                        from shelton,ct

                                                        Verified Buyer

                                                        Pros

                                                          Cons

                                                            Best Uses

                                                              Comments about Tekmar Boiler Control - One Stage Boiler:

                                                              Never worked right. Removed it and installed
                                                              honeywell outdoor reset that workes great

                                                              • Primary use:
                                                              • Personal

                                                              Displaying reviews 1-9

                                                              Back to top

                                                              Q&A: Ask the Questions, share answers

                                                              Do you have questions about this product?

                                                              get answers from real customers and in-house experts with AnswerBox.

                                                              17 Questions | 23 Answers
                                                              Displaying questions 1-10Previous | Next »
                                                              • Tekmar Boiler Control - One Stage Boiler

                                                                Q:

                                                                Is this capable of post purging circulators for a while after the thermostat ends it's call for heat? If not, is there something that will do that in conjunction with this device?
                                                                Asked on 3/26/2012 by learning

                                                                5 answers

                                                                • VERIFIED BUYER

                                                                  A:

                                                                  No, the Tekmar 256 will not do this. I installed one about 2 years ago and am very pleased with it's performance. It has worked flawlessly so far. With my installation I did have to install an additional RIB(relay in a box). As far as I know there is no "out of the box" component to accomplish "post purging". It probably does not pay to pursue trying to accomplish this since the 256 adjusts the boiler temp. For example, if the outdoor temp was 45 degrees the 256 may adjust the boiler temp to 140 degrees. To run the circulator for a set amount of time at lower temps may be just a waste of electric. You would be better off installing an automatic vent damper if you don't already have one. This will prevent the heat of the boiler from going up the flue during standby. I would leave this to the pros though as it could be dangerous if installed improperly.

                                                                  Answered on 3/27/2012 by Another PexSupply Customer
                                                                • VERIFIED BUYER

                                                                  A:

                                                                  I'm not sure what is meant by "post purging circulators".  Having said that, this unit only serves to turn on and off the boiler fire based on a temperature curve that relates the boiler temperature with the outside air temperature.  Thermostatic control of individual zone circulators is unaffected.  Hope this helps.
                                                                  Howard Levy

                                                                  Answered on 3/27/2012 by Another PexSupply Customer
                                                                • VERIFIED BUYER

                                                                  A:

                                                                  I am using the Tekmar #256 for outdoor reset, in conjunction with a Honeywell #8124 Triple Aquastat, with the thermostat as the control of when the circulator, and the boiler, run. Ifis not nothing runs. I still get some short cycling due to imperfect coordination between ermostat and the aquastat (Tekmar). I do not find that the Tekmar control provides circulator run on when the thermostat is not calling for heat. Don't know if it can be set up to do that. Try downloading the manual from the Tekmar website: http://tekmarcontrols.com/hvacsystems/256.html. You may find the answer there. Good luck.

                                                                  Answered on 3/27/2012 by Another PexSupply Customer
                                                                • VERIFIED BUYER

                                                                  A:

                                                                  Call the mfg of the circulator that you are using never heard of a post purging circulators before

                                                                  Answered on 3/27/2012 by Another PexSupply Customer
                                                                • VERIFIED BUYER

                                                                  A:

                                                                  If you use a Tekmar 260 control this would have a 20 second post purge
                                                                  feature on the pump. The 265 has no wiring for a pump. You could put a
                                                                  delay off timer in the pump circuit for the boiler if you use the 265
                                                                  control.

                                                                  Answered on 3/26/2012 by Dbon from Pittsburgh
                                                              • Tekmar Boiler Control - One Stage Boiler

                                                                Q:

                                                                Will the 256 work with a Weil McLain GV4 boiler? Would an extra relay be needed?
                                                                Asked on 12/20/2011 by Anonymous

                                                                2 answers

                                                                • CUSTOMER CARE

                                                                  A:

                                                                  Yes, the 256 control will work with a Weil-McLain GV-4 boiler. You will not need an extra relay.

                                                                  Answered on 12/23/2011 by PexSupply Staff from NY
                                                                • A:

                                                                  Yes, this control will work with your boiler.

                                                                  Answered on 1/3/2012 by Anonymous from None
                                                              • Tekmar Boiler Control - One Stage Boiler

                                                                Q:

                                                                I have a zoned system with fin tubes in the basement, and cast iron radiators in the rest of the house. Can a single Tekmar 256 be used in this setup, and if so, which "terminal unit" should be selected in the configuration?
                                                                Asked on 10/31/2011 by Eric from Saint Paul, MN

                                                                1 answer

                                                                • CUSTOMER CARE

                                                                  A:

                                                                  Yes you can use this control for your setup. We would recommend using the Fin–tube Convector (4) setting.

                                                                  Answered on 11/2/2011 by PexSupply Staff from NY
                                                              • Tekmar Boiler Control - One Stage Boiler

                                                                Q:

                                                                will this control work with Utica MGB piped as primary/secondary?

                                                                when the boiler is reset by controller, will the vent damper close until it's ready to fire again?
                                                                Asked on 10/19/2011 by rhubarb42 from Baltimore

                                                                1 answer

                                                                • CUSTOMER CARE

                                                                  A:

                                                                  The Tekmar 256 Boiler Control is a control designed to regulate the supply water temperature from a single boiler based on the outdoor temperature. This control will not operate a vent damper.

                                                                  Answered on 11/8/2011 by PexSupply Staff from NY
                                                              • Tekmar Boiler Control - One Stage Boiler

                                                                Q:

                                                                I have gas-fired boiler Smith model GBX with standing pilot. I cannot find boiler demand switch on wiring and connection diagram. What are points of connection Tekmar 260 to my boiler control?

                                                                Thank you
                                                                Asked on 10/1/2011 by Mike from Connecticut

                                                                1 answer

                                                                • CUSTOMER CARE

                                                                  A:

                                                                  Contacts 5 and 6 on the Tekmar 256 control are for the boiler.

                                                                  Answered on 10/4/2011 by PexSupply Staff from NY
                                                              • Tekmar Boiler Control - One Stage Boiler

                                                                Q:

                                                                Will this work with my setup. Single boiler has two zones/circulators (Taco 503 controller) one of the two zones is a 40 gal water tank that is fed from the boiler, does not have its own heat source.
                                                                Asked on 9/16/2011 by JJ from Portland, ME

                                                                1 answer

                                                                • CUSTOMER CARE

                                                                  A:

                                                                  No, you will need to use the Tekmar 260 control in this situation.

                                                                  Answered on 9/21/2011 by PexSupply Staff from NY
                                                              • Tekmar Boiler Control - One Stage Boiler

                                                                Q:

                                                                Will this device work with a ground-source heat-pump that's supplying a radiant system?
                                                                Asked on 5/4/2011 by tlbranth from carnation, wa

                                                                1 answer

                                                                • CUSTOMER CARE

                                                                  A:

                                                                  As far as we know, it will not. You may want to check with the heat pump manufacturer.

                                                                  Answered on 5/5/2011 by PexSupply Staff from NY
                                                              • Tekmar Boiler Control - One Stage Boiler

                                                                Q:

                                                                Is there any energy savings with this control, if so how much?
                                                                Asked on 3/5/2011 by Dave from Denver CO

                                                                1 answer

                                                                • CUSTOMER CARE

                                                                  A:

                                                                  You should save about 10%-15% with this control.

                                                                  Answered on 3/7/2011 by PexSupply Staff from NY
                                                              • Tekmar Boiler Control - One Stage Boiler

                                                                Q:

                                                                Will this controller work with my Weil McClain CGa boiler?
                                                                Asked on 2/21/2011 by Green from MA

                                                                1 answer

                                                                • CUSTOMER CARE

                                                                  A:

                                                                  Yes, this control will work.

                                                                  Answered on 2/22/2011 by PexSupply Staff from NY
                                                              • Tekmar Boiler Control - One Stage Boiler

                                                                Q:

                                                                Will this control work with a Weil-McLain CGM-5 natural gas 2 zone system?
                                                                Asked on 2/12/2011 by Tim the tinkerer from Ohio

                                                                1 answer

                                                                • CUSTOMER CARE

                                                                  A:

                                                                  Yes, it will.

                                                                  Answered on 2/15/2011 by PexSupply Staff from NY
                                                              Displaying questions 1-10Previous | Next »

                                                              Do you have a question about this product? 

                                                              PexSupply.com Logo

                                                              Join Our Mailing List - Sign up and receive special offers and coupons

                                                              Nextag Seller PriceGrabber User Ratings for Pex Supply PHCC BBB Reliability Seal
                                                              HACKER SAFE certified sites prevent over 99.9% of hacker crime. Facebook Twitter Youtube