Application: Single Boiler
Stages:
?
1
Width: 7-9/16"
Height: 6-5/8"
User Interface: Push Button
LCD
Voltage:
?
240v
Depth: 2-13/16"
Ambient Conditions: Indoor Only: 32°-113°F < 90% RH non-condensing
Power Supply: 120V (ac)
Relays: 240 V (ac) 10 A-1/3 hp- pilot duty 240 VA
Temperature Range (F): -67°-266°F
Control: Microprocessor PID control
Weight: 3 lbs
Demands: 20 to 260 V (ac) 2 VA
Sensors: NTC Thermistor
10 k ohm @ 77°F

Description for Tekmar 260


The Tekmar 260 boiler control is a microprocessor-based control designed to regulate the supply water temperature from a single boiler based on either outdoor air temperature or a DHW demand. The 260 can control either a DHW pump or valve and provide DHW Priority. A tekmar indoor sensor can be connected to the Tekmar 260 in order to provide indoor temperature feedback from the heating system.
Tekmar 260 Specifications:
Literature: D 260, A 260's, D 001, D 070
Control: Microprocessor PID control; This is not a safety (limit) control
Packaged Weight: 3.0 lb. (1340 g), Enclosure A, blue PVC plastic
Dimensions: 6-5/8" H x 7-9/16" W x 2-13/16" D (170 x 193 x 72 mm)
Approvals: CSA C US, meets ICES & FCC regulations for EMI/RFI
Ambient Conditions: Indoor use only, 32 to 113+F (0 to 45+C), < 90% RH non-condensing
Power Supply: 120 V +10% 50/60 Hz 1300 VA
Relays: 240 V (ac) 10 A 1/3 hp, pilot duty 240 VA
Demands: 20 to 260 V (ac) 2 VA
Sensors Included: NTC thermistor, 10 k? @ 77+F (25+C +0.2+C) +=3892 Outdoor Sensor 070 and Universal Sensor 071
Optional Devices: Tekmar type #: 031, 032, 076, 077

Boiler Control - One Stage Boiler & DHW

REVIEW SNAPSHOT®

by PowerReviews
Tekmar Boiler Control - One Stage Boiler & DHW
 
4.5

(based on 4 reviews)

Ratings Distribution

  • 5 Stars

     

    (2)

  • 4 Stars

     

    (2)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (0)

100%

of respondents would recommend this to a friend.

Pros

    Cons

      Best Uses

          • Primary use:
          • Personal (3)

        Reviewed by 4 customers

        Sort by

        Displaying reviews 1-4

        Back to top

         
        5.0

        Great Product

        By chico

        from Pennsylvania

        Verified Buyer

        Pros

          Cons

            Best Uses

              Comments about Tekmar Boiler Control - One Stage Boiler & DHW:

              a great product to save on fuel costs

              • Primary use:
              • Personal
               
              4.0

              Used to stop overheating

              By Rubin

              from New Jersey

              Verified Reviewer

              Pros

                Cons

                  Best Uses

                    Comments about Tekmar Boiler Control - One Stage Boiler & DHW:

                    I have a five zone (two radiant floor, 3 cast iron radiator) system on newer non-condensing Utica gas boiler and had a problem with the house overheating. After t-stat stopped calling for heat and zones and boiler shut off the house would still build about to about 10 degrees over t-stat setting (this was at 160 degree water temp). Lowering boiler temp to solved problem but on cold days house was too cold! Tekmar 260 solved the problem! My only wish was that it had an relay for 120volt power connected to the warm weather shutdown feature that could be used to power my zone circulators. Tekmar's only solution for zoning is the more expensive TN4 system with multiple add on cards. I added my own WWSD for the zone circulators with a RANCO temp relay. Overall, the 260 is great and very smart. Not sure about savings because I had also added a zone in the basement but gas bills seem to be about same or little less that previous years. System is a true primary-secondary, three zone circulators (one with three zone valves for radiator zones) with boiler by-pass loop. I do not use the indirect domestic water heater feature but piped it for future use.

                    • Primary use:
                    • Personal
                     
                    5.0

                    A WORTHY PRODUCT

                    By JOE D.

                    from WILLIAMSVILLE N.Y.

                    Pros

                      Cons

                        Best Uses

                          Comments about Tekmar Boiler Control - One Stage Boiler & DHW:

                          I had this unit installed in my 8 unit apt bldg, to use on HW Boiler...after 1 year, my bal. billing went from $420, to $275/month. A great savings due to less usage. Installing them on all my buildings.

                          • Primary use:
                          • Business
                           
                          4.0

                          Tekmar 260 Boiler Control

                          By Bernie78

                          from Manistee, Mi

                          Verified Buyer

                          Pros

                            Cons

                              Best Uses

                                Comments about Tekmar Boiler Control - One Stage Boiler & DHW:

                                The Tekmar 260 was easy to install and the directions to do so were very good. It is a good looking control and easily mountable. I still have to see how it works with my existing boiler controls during the winter months.

                                • Primary use:
                                • Personal

                                Displaying reviews 1-4

                                Back to top

                                Q&A: Ask the Questions, share answers

                                Do you have questions about this product?

                                get answers from real customers and in-house experts with AnswerBox.

                                10 Questions | 10 Answers
                                Displaying questions 1-10
                                • Tekmar Boiler Control - One Stage Boiler & DHW

                                  Q:

                                  Where can I buy the optional timer I think the model number is 30
                                  Asked on 1/30/2012 by Albert

                                  1 answer

                                • Tekmar Boiler Control - One Stage Boiler & DHW

                                  Q:

                                  How do I control a tankless water heater with the Teknar 260?
                                  Asked on 11/7/2011 by Matt from West Stockbridge, MA

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    The Tekmar 260 control is a boiler control, not a tankless water heater control. It will not work with a tankless water heater.

                                    Answered on 11/8/2011 by PexSupply Staff from NY
                                • Tekmar Boiler Control - One Stage Boiler & DHW

                                  Q:

                                  I have a Burnham V74 boiler with 5 heating zones controlled by circulating pumps. I also have an indirect water heater and a spa(presently on a tekmar 150)with circulating pumps also. Is the 401 the best unit or should I consider the 260?
                                  Asked on 9/21/2011 by jed from CT

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    The 260 should work well in this application.

                                    Answered on 9/23/2011 by PexSupply Staff from NY
                                • Tekmar Boiler Control - One Stage Boiler & DHW

                                  Q:

                                  I have a one stage non condensing boiler 2 zones and DHW What con trol would is use the d260 I also have a argo zone controller on it for my pump control
                                  Asked on 9/10/2011 by Anonymous

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    Yes, this unit will work for you.

                                    Answered on 9/12/2011 by PexSupply Staff from NY
                                • Tekmar Boiler Control - One Stage Boiler & DHW

                                  Q:

                                  Will this model replace the techmar 353?
                                  Asked on 6/30/2011 by Steve from Sterling, AK

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    No, the replacement for the Tekmar 353 would be the Tekmar 356.

                                    Answered on 7/1/2011 by PexSupply Staff from NY
                                • Tekmar Boiler Control - One Stage Boiler & DHW

                                  Q:

                                  Dose 260 the same as 251or did it replace it?
                                  Asked on 5/5/2011 by Mike from madison,WI

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    The 260 replaces the 251.

                                    Answered on 5/6/2011 by PexSupply Staff from NY
                                • Tekmar Boiler Control - One Stage Boiler & DHW

                                  Q:

                                  How do you wire in boiler demand?
                                  Asked on 4/5/2011 by Anonymous

                                  1 answer

                                • Tekmar Boiler Control - One Stage Boiler & DHW

                                  Q:

                                  How do i adjust the outside temp sensor
                                  Asked on 10/11/2010 by Eddie the man from NY,NY

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    The temperature sensor can not be adjusted, as it simply reads the outside temperature. If the readings are not accurate, it could be that the sensor is defective, the wiring of the unit is incorrect, or the sensor is not placed in the right location. It should be situated on the north side of the house without exposure to direct sunlight, otherwise the readings could be incorrect.

                                    Answered on 10/12/2010 by PexSupply Staff from NY
                                • Tekmar Boiler Control - One Stage Boiler & DHW

                                  Q:

                                  which tekmar do i need to modulate boiler temp from outdoorsensor with an indhwh
                                  Asked on 9/15/2010 by andy from long island ny

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    As long as you have a one stage boiler, this model would be the correct unit.

                                    Answered on 9/16/2010 by PexSupply Staff from NY
                                • Tekmar Boiler Control - One Stage Boiler & DHW

                                  Q:

                                  what is the warranty on this control?
                                  Asked on 9/7/2010 by andy from new york

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    The warranty period is for a period of twenty-four (24) months from the production date
                                    if the product is not installed during that period, or twelve (12) months from the
                                    documented date of installation if installed within twenty-four (24) months from the
                                    production date.

                                    Answered on 9/7/2010 by PexSupply Staff from NY
                                Displaying questions 1-10

                                Do you have a question about this product? 

                                PexSupply.com Logo

                                Join Our Mailing List - Sign up and receive special offers and coupons

                                Nextag Seller PriceGrabber User Ratings for Pex Supply PHCC BBB Reliability Seal
                                HACKER SAFE certified sites prevent over 99.9% of hacker crime. Facebook Twitter Youtube