Specs

Accessory For: AHE Boilers
GV Boilers
HE II Boilers
Application: Heating

Description for Weil Mclain 382-200-448

Weil McLain gold module conversion kit, includes UT module 1013-200 - for boilers:

  • GV
  • HE II
  • AHE
Replaces Part #: S9301A1001

Integrated Boiler Control Unit (Includes UT Module 1013-200)

REVIEW SNAPSHOT®

by PowerReviews
Weil MclainIntegrated Boiler Control Unit (Includes UT Module 1013-200)
 
4.9

(based on 16 reviews)

Ratings Distribution

  • 5 Stars

     

    (14)

  • 4 Stars

     

    (2)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (0)

100%

of respondents would recommend this to a friend.

Pros

    Cons

      Best Uses

          • Primary use:
          • Personal (15)

        Reviewed by 16 customers

        Sort by

        Displaying reviews 1-10

        Back to top

        Previous | Next »

         
        5.0

        Product worked perfect at first install

        By OneManShow

        from Staten Island, NY

        Verified Buyer

        Pros

          Cons

            Best Uses

              Comments about Integrated Boiler Control Unit (Includes UT Module 1013-200):

              The instructions to install the product were simple. It immediately worked when I first installed it. I highly recommend this product.

              • Primary use:
              • Personal
               
              5.0

              Plug and Play

              By Red L Services

              from Somerset County, New Jersey

              Verified Buyer

              Pros

                Cons

                  Best Uses

                    Comments about Integrated Boiler Control Unit (Includes UT Module 1013-200):

                    Had intermitent lockouts on our 17yr old HEII. It would reset by turning it off, and pushing on the connectors for the pressure switch and ignitor. When I pulled the control board, the circut was damaged - probably by moisture. The new Gold conversion board was a direct replacement. 15 minutes and we were back up and running. No problems since.

                    • Primary use:
                    • Personal
                     
                    5.0

                    Great Quality

                    By fourbases

                    from Galena, il.

                    Verified Buyer

                    Pros

                      Cons

                        Best Uses

                          Comments about Integrated Boiler Control Unit (Includes UT Module 1013-200):

                          Easy installation.

                          • Primary use:
                          • Personal
                           
                          5.0

                          Great Replacement!

                          By R1100S (BMW M/cycle)

                          from Saylorsburg, PA

                          Verified Buyer

                          Pros

                            Cons

                              Best Uses

                                Comments about Integrated Boiler Control Unit (Includes UT Module 1013-200):

                                Slightly different layout appearance, but old wiring receptacles plug right in...takes about 10 minutes to swap the old and new units. I was able to get my old unit to work while waiting for the new control unit by soldering fan motor connections on the board, but wanted the reliability of the new control unit. (New unit arrived in one day after my order... good job, PEX!) My HE II was new in 1992, so I can't really complain about needing to replace this unit.

                                • Primary use:
                                • Personal
                                 
                                5.0

                                Worked fine easy replacement

                                By Warmnow

                                from Waverly, New York

                                Verified Buyer

                                Pros

                                  Cons

                                    Best Uses

                                      Comments about Integrated Boiler Control Unit (Includes UT Module 1013-200):

                                      direct replacment easy and fast to install

                                      • Primary use:
                                      • Personal
                                       
                                      5.0

                                      very easy switch not complicated to do

                                      By dave

                                      from lpool ny

                                      Verified Buyer

                                      Pros

                                        Cons

                                          Best Uses

                                            Comments about Integrated Boiler Control Unit (Includes UT Module 1013-200):

                                            very easy to install plug and play just had to rewire the circulating pump

                                            • Primary use:
                                            • Personal
                                             
                                            5.0

                                            exactly as specified

                                            By skinny skier

                                            from Spokane, WA

                                            Verified Buyer

                                            Pros

                                              Cons

                                                Best Uses

                                                  Comments about Integrated Boiler Control Unit (Includes UT Module 1013-200):

                                                  Installed in minutes and worked perfectly.

                                                  • Primary use:
                                                  • Personal
                                                   
                                                  4.0

                                                  I'm happy !

                                                  By DJLen

                                                  from Fort Erie, Ont

                                                  Verified Buyer

                                                  Pros

                                                    Cons

                                                      Best Uses

                                                        Comments about Integrated Boiler Control Unit (Includes UT Module 1013-200):

                                                        I replaced the old malfunctioning module with this new one and the boiler system is working great. My only disappointment was the product was shipped C.O.D. and I didn't know that before hand or I could have made proper payment arrangements before the product arrived. At the end of the day, all is good.

                                                        • Primary use:
                                                        • Personal

                                                        (1 of 1 customers found this review helpful)

                                                         
                                                        5.0

                                                        Weil-Mclain Boiler Control Module

                                                        By Marty

                                                        from Michigan

                                                        Verified Buyer

                                                        Pros

                                                          Cons

                                                            Best Uses

                                                              Comments about Integrated Boiler Control Unit (Includes UT Module 1013-200):

                                                              Controler works great, its a direct replacement for the United Tech unit 1013-100 GV/HEII

                                                              • Primary use:
                                                              • Personal
                                                               
                                                              5.0

                                                              boiler module

                                                              By Leon

                                                              from Fort Erie, Ont, Canada

                                                              Verified Reviewer

                                                              Pros

                                                                Cons

                                                                  Best Uses

                                                                    Comments about Integrated Boiler Control Unit (Includes UT Module 1013-200):

                                                                    the product arrived in few days, by UPS. I installed the module and works fine. My only complaint was I wish I knew UPS was looking for cod payment. If I would've knew when ordering, I could have made arrangements to have a check or credit card info available for the driver, otherwise, I would recommend this product and company

                                                                    • Primary use:
                                                                    • Personal

                                                                    Displaying reviews 1-10

                                                                    Back to top

                                                                    Previous | Next »

                                                                    Q&A: Ask the Questions, share answers

                                                                    Do you have questions about this product?

                                                                    get answers from real customers and in-house experts with AnswerBox.

                                                                    5 Questions | 14 Answers
                                                                    Displaying questions 1-5
                                                                    • Integrated Boiler Control Unit (Includes UT Module 1013-200)

                                                                      Q:

                                                                      I have a GV Series 4 and installed control module ut-1013-200
                                                                      do I need the Molex plug installed to the module?
                                                                      Asked on 3/13/2012 by Anonymous

                                                                      6 answers

                                                                      • VERIFIED BUYER

                                                                        A:

                                                                        If you are using it on a boiler without a power vent damper you would need to install the plug.
                                                                        Mike

                                                                        Answered on 3/14/2012 by Another PexSupply Customer
                                                                      • VERIFIED BUYER

                                                                        A:

                                                                        I am not sure if I can help. The only thing I had trouble with was the
                                                                        wires from the igniter did not fit the new board - it seems it needed a
                                                                        separate part to connect correctly to the board. I used the connection
                                                                        from the old igniter - to connect to the igniter and twisted the other ends
                                                                        and inserted into the connections on the new board. (This was the mismatch
                                                                        for me) I am not sure what you mean by the Molex Plug?
                                                                        Do not know if this helps.

                                                                        Answered on 3/14/2012 by Another PexSupply Customer
                                                                      • VERIFIED BUYER

                                                                        A:

                                                                        No, but I did go ahead and replace the wiring from the circulator pump to the module that was included.

                                                                        Answered on 3/14/2012 by Another PexSupply Customer
                                                                      • VERIFIED BUYER

                                                                        A:

                                                                        Only if the end is different on the module then the Cord.

                                                                        Answered on 3/14/2012 by Another PexSupply Customer
                                                                      • VERIFIED BUYER

                                                                        A:

                                                                        I had the original 1013-100 control module which I replaced with a new 1013-200 module on my Weil McLain GV Series 4 Boiler. The instructions for GV 4 owners that came with the new module said to "discard wire harness assembly with plastic bag attached" referring to the new wire harness that came with the new module. I did this and installed the new module using the old original wire harness (which didn't seem to plug into the new module properly) and the circuit breaker blew.
                                                                        So, I wired in the new harness which fit the plugs on the module better but then the Limit Circuit LED on the module flashed constantly. Once I plugged in the new Molex plug (that was in the plastic bag attached to the new harness that the instructions said to discard) everything started working fine. This Molex plug, I guess, is a 47K resistor that plugs into the module circuit board next to a two pole receptacle marked P8.
                                                                        Hope this helps...it's not the way the instructions say to do it but it works fine and has for over 4 months now with no troubles.

                                                                        Answered on 3/13/2012 by Another PexSupply Customer
                                                                      • VERIFIED BUYER

                                                                        A:

                                                                        Which is the Molex plug, I simply replaced the old with the new. I can tell you that it will work if you use a separate power supply for the pump.

                                                                        Answered on 3/13/2012 by Another PexSupply Customer
                                                                    • Integrated Boiler Control Unit (Includes UT Module 1013-200)

                                                                      Q:

                                                                      We installed the boiler control unit to our Weil McLain HE II, and it seems to be running, but the "limit" light is constantly flickering on and off. Is that okay?
                                                                      Asked on 12/1/2011 by Lisa from Queens, NY

                                                                      2 answers

                                                                      • A:

                                                                        I had the same problem. Once I plugged in the new Molex plug (that was in the plastic bag attached to the new harness that the instructions said to discard) everything started working fine, no more limit light flickering. This Molex plug, I guess, is a 47K resistor that plugs into the module circuit board next to a two pole receptacle marked P8.

                                                                        Hope this helps...it's not the way the instructions say to do it but it works fine and has for over 4 months now with no troubles.

                                                                        Answered on 3/14/2012 by boilerfan from main street, USA
                                                                      • A:

                                                                        Do you have a higher amp draw circulators such as the B & G 100 or the Taco 110, if so you need to use an isolation relay to avoid damaging the control unit. This could be the cause of the limit light flickering on and off.

                                                                        Answered on 12/8/2011 by Anonymous from None
                                                                    • Integrated Boiler Control Unit (Includes UT Module 1013-200)

                                                                      Q:

                                                                      Hi,

                                                                      My Weil Mclain HE II ,natural gas boiler,needs a replacement for its boiler control unit made by United Technologies and has the number 1013-100.Will the above pictured product be the correct replacement ?
                                                                      Asked on 4/11/2011 by Anonymous from long Island,N.Y.

                                                                      4 answers

                                                                      • A:

                                                                        I had the original 1013-100 control module which I replaced with a new 1013-200 module on my Weil McLain GV Series 4 Boiler. The instructions for GV 4 owners that came with the new module said to "discard wire harness assembly with plastic bag attached" referring to the new wire harness that came with the new module. I did this and installed the new module using the old original wire harness (which didn't seem to plug into the new module properly) and the circuit breaker blew.

                                                                        So, I wired in the new harness which fit the plugs on the module better but then the Limit Circuit LED on the module flashed constantly. Once I plugged in the new Molex plug (that was in the plastic bag attached to the new harness that the instructions said to discard) everything started working fine. This Molex plug, I guess, is a 47K resistor that plugs into the module circuit board next to a two pole receptacle marked P8.

                                                                        Answered on 3/14/2012 by boilerfan from main street, USA
                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        According to the manufacturer, 382-200-448 is the correct replacement part.

                                                                        Answered on 4/13/2011 by PexSupply Staff from NY
                                                                      • VERIFIED BUYER

                                                                        A:

                                                                        This will definitely work. I installed one on my Weil Mclain.

                                                                        Answered on 7/21/2011 by Stephen the Plumber/Electrician from Ely, MN
                                                                      • VERIFIED BUYER

                                                                        A:

                                                                        This is most likely a little late for you, but yes it will. I used it to replace the same board.

                                                                        Answered on 12/5/2011 by skinny skier from Spokane, WA
                                                                    • Integrated Boiler Control Unit (Includes UT Module 1013-200)

                                                                      Q:

                                                                      where is the wire harness
                                                                      Asked on 3/29/2011 by Anonymous

                                                                      1 answer

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        The conversion kit includes a circulator wiring harness and a temperature sensor jumper to allow the new module to be used on older boilers. There are no other wiring harnesses in the kit.

                                                                        Answered on 4/4/2011 by PexSupply Staff from NY
                                                                    • Integrated Boiler Control Unit (Includes UT Module 1013-200)

                                                                      Q:

                                                                      Can an outdoor reset be attached to this unit?
                                                                      Asked on 1/1/2011 by Anonymous

                                                                      1 answer

                                                                      • CUSTOMER CARE

                                                                        A:

                                                                        No, you cannot plug an outdoor reset directly into this unit.

                                                                        Answered on 1/19/2011 by PexSupply Staff from NY
                                                                    Displaying questions 1-5

                                                                    Do you have a question about this product? 

                                                                    PexSupply.com Logo

                                                                    Join Our Mailing List - Sign up and receive special offers and coupons

                                                                    Nextag Seller PriceGrabber User Ratings for Pex Supply PHCC BBB Reliability Seal
                                                                    HACKER SAFE certified sites prevent over 99.9% of hacker crime. Facebook Twitter Youtube