TruFLOW Manifold, 8-loop S&R Zoom

TruFLOW Manifold, 8-loop S&R

SKU:A2610800

Brand: Uponor (Wirsbo)

Uponor (Wirsbo)
Qty Price
$515.95
/ each
In Stock! Ships in 24-48 Hours
7 Available

Specs

Number of Outlets: 8
PEX Size: 3/8"
1/2"
5/8"
5/16"
Supply Size: R32
Loop Size: R20
Material: Brass
Application: Heating
Fitting System Compatibility: PEX Compression
PEX-AL-PEX Compression
Manifold Compatibility: Truflow
Tubing Compatibility: PEX-AL-PEX
PEX

Description for Uponor (Wirsbo) A2610800

TrueFLOW Manifold without Flow/Temperature Meters come fully assembled ready for installation. The TruFLOW balancing Hex Key is used on the internal balancing valves of the supply manifold to balance the loops across the manifold. Manifold is shipped with the appropriate number of Actuator Adapters (A2630028). Maximum recommended flow to the manifold based on manifold body diameter is 21.0 gpm.
Note: The Flow Meters (A2640015 and A2640027) are purchased separately and installed on the return manifold.

TruFLOW Manifold, 8-loop S&R

REVIEW SNAPSHOT®

by PowerReviews
Uponor (Wirsbo)TruFLOW Manifold, 6-loop S&R
 
5.0

(based on 1 review)

Ratings Distribution

  • 5 Stars

     

    (1)

  • 4 Stars

     

    (0)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (0)

Reviewed by 1 customer

Displaying review 1

Back to top

(1 of 1 customers found this review helpful)

 
5.0

Great product easy to hook-up.

By Heff of the Peff

from Toronto, Canada

Verified Buyer

Comments about Uponor (Wirsbo) TruFLOW Manifold, 8-loop S&R:

Very heavy duty construction should last a lifetime.

Displaying review 1

Back to top

Q&A: Ask the Questions, share answers

Do you have questions about this product?

get answers from real customers and in-house experts with AnswerBox.

11 Questions | 12 Answers
Displaying questions 1-10Previous | Next »
  • Uponor (Wirsbo) TruFLOW Manifold, 4-loop S&R

    Q:

    I have some buildup preventing one of the loops in the TruFLOW Manifold from closing and hot water bleeding by that loop when the pump is running providing heat to one of the other loops. Can I disassemble the loop and clean out that valve?
    I have one ball valve going in the supply loop to the floor above and not a way to shut off the return water line to the Manifold which as the defective valve controlled with the Uponor Thermal Actuator. Can I turn off the water to the supply line and will this prevent the water from leaking out of the manifold when I disassemble the valve?
    Asked on 1/7/2012 by Anonymous from port townsend, Washington

    1 answer

    • CUSTOMER CARE

      A:

      Yes, you can clean the valve. You'll have to drain the system down in order to remove the valve.

      Answered on 1/12/2012 by PexSupply Staff from NY
  • Uponor (Wirsbo) TruFLOW Manifold, 7-loop S&R

    Q:

    Can i use this upside down. I need to feed it from the top. Is there a gasket between the end cap and 1" conector A4133210?
    Asked on 10/25/2011 by Anonymous

    1 answer

    • CUSTOMER CARE

      A:

      The manifold can be mounted upside down, but any flow meters would not be able to operate. The A4133210 ProPEX adapter screws either directly into the manifold or into TruFLOW Manifold Supply and Return Ball Valves without any gasket.

      Answered on 11/23/2011 by PexSupply Staff from NY
  • Uponor (Wirsbo) TruFLOW Manifold, 2-loop S&R

    Q:

    can i manually close the idividual port on a two loop manifold
    Asked on 10/19/2011 by Anonymous

    1 answer

    • CUSTOMER CARE

      A:

      Yes, you can shut off flow using the included hex key wrench.

      Answered on 10/20/2011 by PexSupply Staff from NY
  • Uponor (Wirsbo) TruFLOW Manifold, 8-loop S&R

    Q:

    How does the air bleeder vent work with this manifold? Does a seperate automatic air vent need to be installed?
    Asked on 10/15/2011 by Anonymous

    1 answer

    • CUSTOMER CARE

      A:

      You do not need to install a separate automatic air vent, but it would help with the air-bleeding process.

      Answered on 10/18/2011 by PexSupply Staff from NY
  • Uponor (Wirsbo) TruFLOW Manifold, 4-loop S&R

    Q:

    Can I switch the supply and return so the supply is on top?
    Asked on 10/13/2011 by Anonymous from ny

    1 answer

    • CUSTOMER CARE

      A:

      Yes, you can switch the orientation of the manifold in the brackets.

      Answered on 10/14/2011 by PexSupply Staff from NY
  • Uponor (Wirsbo) TruFLOW Manifold, 12-loop S&R

    Q:

    what are the product dimensions?
    Asked on 7/26/2011 by Anonymous from Long Island

    1 answer

  • Uponor (Wirsbo) TruFLOW Manifold, 5-loop S&R

    Q:

    Can this manifold be placed horizontally?
    Asked on 5/16/2011 by Anonymous

    1 answer

    • CUSTOMER CARE

      A:

      Yes, it can.

      Answered on 5/17/2011 by PexSupply Staff from NY
  • Uponor (Wirsbo) TruFLOW Manifold, 5-loop S&R

    Q:

    Is there an adaptor for this manifold for 3/4 inch supply and return PEX?
    Asked on 3/26/2011 by Anonymous

    1 answer

    • CUSTOMER CARE

      A:

      You can do this in two ways: either using parts A4143225 and A4020750 or just part Q4143275.

      Answered on 3/29/2011 by PexSupply Staff from NY
  • TruFLOW Manifold, 6-loop S&R

    Q:

    I am using 1" copper for my radiant system. What adapters do I need to sweat to the manifold. Also do I need end caps or does it come with them.
    Asked on 12/24/2010 by Anonymous

    1 answer

    • CUSTOMER CARE

      A:

      Part number A4133210 will connect from the manifold to 1" Copper pipe. The end caps will not be needed for the supply lines, as the other end is sealed.

      Answered on 12/28/2010 by PexSupply Staff from NY
  • Uponor (Wirsbo) TruFLOW Manifold, 12-loop S&R

    Q:

    I assume the nuts come with it and not just the compression fitting?
    Asked on 11/23/2010 by Anonymous

    1 answer

    • CUSTOMER CARE

      A:

      The TruFLOW manifolds do not come with any fittings.

      Answered on 11/29/2010 by PexSupply Staff from NY
Displaying questions 1-10Previous | Next »

Do you have a question about this product? 

PexSupply.com Logo

Join Our Mailing List - Sign up and receive special offers and coupons

Nextag Seller PriceGrabber User Ratings for Pex Supply PHCC BBB Reliability Seal
HACKER SAFE certified sites prevent over 99.9% of hacker crime. Facebook Twitter Youtube